8732E Field Mount Magnetic Flowmeter Transmitter – Rosemount ™

  • Sensor Compatibility: Compatible with Rosemount 8705, 8711 and 8721 sensors. Compatible with AC powered sensors. etc. from other manufacturers.
  • Transmitter coil supply current: 500mA
  • Flow range: ability to process signals from fluids moving at speeds between 0.01 and 12 m / s (0.04 and 39 ft / s) for both normal and reverse flow in all sizes of sensors. Full scale continuously adjustable between -12 and 12 m / s (between -39 and 39 ft / s).
  • Conductivity limits: the process liquid must have a conductivity of 5 microSiemens / cm (5 micromhos / cm) or greater
    Power supply: 90-250 V AC, 50/60 Hz or 12-42 V DC
  • Line Power Fuses: 90-250 VAC Systems – 1 A, 250 V, I2t, 1.5 A2s nominal, fast acting Bussman AGC-1, Littelfuse 31201.5HXP – 12-42 VDC systems – 3 Amp, 250 V, I2t, 14 A2s nominal, fast acting Bel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135
  • Line Power Fuses: 15 W DC maximum – 40 VA maximum AC
  • Trigger Current: AC: Maximum 35.7A (<5ms) at 250VAC – DC: maximum 42 A (<5 ms) at 42 V DC